Details
The Cisco® ONS 15454 Multiservice Transport Platform (MSTP) provides a comprehensive, intelligent dense wavelength-division multiplexing (DWDM) solution for expanding metropolitan-area (metro) and regional bandwidth.
Product Overview
Figure 1

Table 1. Optical Filter Cards with Applications
Component |
Deployment Application |
32-channel multiplexer and demultiplexer
|
This product provides wavelength access (on or off ramp) for all the channels in a fiber cable. Typical deployment locations are terminal hub sites, including service provider central offices or enterprise telecommunications facilities. |
Band-optical add/drop filters (B-OADM)
|
These filters allow access (add/drop) to a band or bands of frequencies from a fiber cable while passing the remaining frequencies. They are typically deployed at intermediate sites where access to greater bandwidth is required. They can also be inserted where future access to bandwidth may be required. |
Channel-optical add/drop filters (C-OADM)
|
These filters enable access (add/drop) to individual wavelengths from a fiber cable while allowing the remaining frequencies to pass. They are deployed at intermediate sites where access to individual wavelengths is necessary. They can be cascaded to provide from 1- to 32-channel add/drop capabilities. |
4-channel multiplexer/demultiplexer (4MD)
|
This product provides wavelength access (on or off ramp) to four channels from a band-OADM filter. They are deployed at intermediate sites where access to individual wavelengths is necessary. |
Figure 2

Figure 3

Figure 4

Product Specifications
Table 2. Regulatory Compliance1
ANSI System |
ETSI System |
Countries
|
|
Canada, United States, Mexico, Korea, Japan, European Union |
European Union, Australia, New Zealand, Singapore, China, Mexico, Hong Kong, Korea |
EMC emissions (radiated, conducted)
|
|
• ICES-003
• GR-1089-CORE
• 47CFR15
• VCCI V-3/2000.04
• CISPR24
|
• EN 300 386-TC
• EN50081-1
• EN55022
• AS/NZS3548, Amendment 1 + 2 1995
|
EMC immunity
|
|
• GR-1089-CORE
• CISPR24
• EN50082-2
|
• EN300-386-TC
• EN55024
|
Safety
|
|
• CAN/CSA-C22.2 No. 60950-00 Third Ed., 12/1/2002
• GR-1089-CORE
• GR-63-CORE
• TS001
|
• UL 60950 Third Ed., 12/1/2000
• EN60950 (to A4)
• IEC60950/EN60950, Third Ed.
• AS/NZS3260 Supplement 1, 2, 3, 4, 1997
|
Environmental
|
|
• GR-63-CORE
• AT&T Network Equipment Design Specifications (NEDS)
|
• ETS 300-019 (Class 3.1E) (Note 2)
|
Structural dynamics
|
|
• GR-63-CORE
• AT&T NEDS
|
• ETS 300-019 (Class 3.1E) (Note 2)
|
Power and grounding
|
|
• SBC (TP76200MP)
• ETS 300-132-1 (DC power)
|
• ETS 300-253 (grounding)
|
Optical
|
|
• GR-253-CORE
• G.692
|
|
Quality
|
|
• TR-NWT-000332, Issue 4, Method 1 calculation for 20-year mean time between failure (MTBF)
|
Table 3. System Requirements
Component |
Cisco ONS 15454 ANSI |
Cisco ONS 15454 ETSI |
Processor
|
TCC2P/TCC2 |
TCC2P/TCC2 |
Cross-connect
|
All (not required) |
All (not required) |
Shelf assembly
|
15454-SA-HD or 15454-SA-HD-DDR shelf assembly with FTA3 version fan-tray assembly |
15454-SA-ETSI shelf assembly with SDH 48V fan-tray assembly |
System software
|
Release 4.6.0 ANSI or later |
Release 4.6.0 ETSI or later |
Table 4. Common Fixed Optical Filter Specifications
Specification |
32-Channel Multiplexer |
32-Channel Demultiplexer |
4-Channel Multiplexer/ Demultiplexer |
Channel OADM Cards |
Band OADM Cards |
Management
|
|||||
Card LEDs Failure (FAIL)
Active/standby (ACT/STBY)
Signal fail (SF)
|
Red Green/yellow Yellow |
Red Green/yellow Yellow |
Red Green/yellow Yellow |
Red Green/yellow Yellow |
Red Green/yellow Yellow |
Operating environment
|
|||||
Temperature |
-5 to 55°C 23 to 131°F |
-5 to 55°C 23 to 131°F |
-5 to 55°C 23 to 131°F |
-5 to 55°C 23 to 131°F |
-5 to 55°C 23 to 131°F |
Humidity |
5 to 95% RH |
5 to 95% RH |
5 to 95% RH |
5 to 95% RH |
5 to 95% RH |
Storage environment
|
|||||
Temperature |
-40 to 85°C -40 to 185°F |
-40 to 85°C -40 to 185°F |
-40 to 85°C -40 to 185°F |
-40 to 85°C -40 to 185°F |
-40 to 85°C -40 to 185°F |
Humidity |
5 to 95% RH |
5 to 95% RH |
5 to 95% RH |
5 to 95% RH |
5 to 95% RH |
Multiplexer and Demultiplexer Filters
Figure 5

Figure 6

Table 5. Specifications for 32-Channel Multiplexer, 32-Channel Demultiplexer, and 4-Channel Multiplexer/Demultiplexer
Specification |
32-Channel Multiplexer |
32-Channel Demultiplexer |
4-Channel Multiplexer/Demultiplexer |
Optical parameters
|
|||
Insertion loss (maximum at minimum VOA) Drop or add
Monitor
|
8.5 dB 29.5 dB |
8.5 dB - |
3.6 (multiplexer), 3.2 (demultiplexer) - |
VOA dynamic range |
25 dB |
25 dB |
30 dB |
Maximum input power |
25 dBm |
25 dBm |
25 dBm |
Filter type |
Array wave guide (AWG) |
AWG |
Interferential |
Minimum transmit filter passband (at 0.5 dB resolution bandwidth) |
±0.18 nm |
±0.18 nm |
±0.18 nm |
Adjacent crosstalk |
23 dB |
23 dB |
25 dB |
Non-adjacent crosstalk |
30 dB |
30 dB |
38 dB |
Total crosstalk |
20 dB |
20 dB |
22 dB |
Maximum polarization dependent loss (PDL) |
1.6 dB |
1.6 dB |
0.7 dB |
Optical power setting accuracy |
±0.5 dB |
±0.5 dB |
±0.5 dB |
Minimum return loss |
40 dB |
40 dB |
40 dB |
Connectors
|
|||
Channel input (multiplexer) and output (demultiplexer) ports Composite ports Monitor ports |
MPO LC LC |
MPO LC - |
LC LC - |
Power
|
|||
Card power draw Typical
Maximum
|
16W 31W |
16W 31W |
17W 25W |
Physical
|
|||
Size |
2 slots |
2 slots |
1 slot |
Supported shelf slots |
1-6, 12-17 |
1-6, 12-17 |
1-6, 12-17 |
Optical Add/Drop Filters
Figure 7

Figure 8

Table 6. Channel OADM Filter Specifications
Specification |
One-Channel OADM |
Two-Channel OADM |
Four-Channel OADM |
Optical parameters
|
|||
Insertion loss (maximum) Drop (maximum)
Add (at minimum VOA)
Express (maximum from express input to composite output)
Express (maximum from composite input to express output)
|
2 dB 2.6 dB 1.2 dB 2.4 dB |
2.4 dB 3.1 dB 1.6 dB 2.7 dB |
5.5 dB 4.9 dB 1.2 dB 2.7 dB |
VOA dynamic range |
30 dB |
30 dB |
30 dB |
Maximum input power |
25 dBm |
25 dBm |
25 dBm |
Filter type |
Interferential |
Interferential |
Interferential |
Minimum transmit filter passband (at 0.5 dB resolution bandwidth) |
+0.18 nm |
+0.18 nm |
+0.18 nm |
Adjacent crosstalk |
25 dB |
25 dB |
25 dB |
Non-adjacent crosstalk |
38 dB |
38 dB |
38 dB |
Total crosstalk |
22 dB |
22 dB |
22 dB |
Maximum polarization dependent loss (PDL) |
0.7 dB |
0.7 dB |
0.7 dB |
Optical power setting accuracy |
+0.5 dB |
+0.5 dB |
+0.5 dB |
Minimum return loss |
40 dB |
40 dB |
40 dB |
Connectors
|
|||
Input/output ports Monitor ports |
LC LC |
LC LC |
LC LC |
Power
|
|||
Card power draw Typical
Maximum
|
17W 25W |
17W 25W |
17W 25W |
Physical
|
|||
Size |
1 slot |
1 slot |
1 slot |
Supported shelf slots |
1-6, 12-17 |
1-6, 12-17 |
1-6, 12-17 |
Figure 9

Table 7. Band OADM Filter Specifications
Specification |
One-Band OADM |
Four-Band OADM |
Optical parameters
|
||
Insertion loss (maximum) Drop path (at minimum VOA)
Add path
Express - From express input to composite output
Express - From composite input to express output (at minmum VOA)
|
3 dB 2.2 dB 1.6 dB 2.9 dB |
4.5 dB 3.5 dB 3 dB 4.9 dB |
VOA dynamic range |
30 dB |
30 dB |
Maximum input power |
25 dBm |
25 dBm |
Filter type |
Interferential |
Interferential |
Minimum filter passband (at -1 dB) |
3.49 nm |
3.49 nm |
Adjacent crosstalk |
25 dB |
25 dB |
Non-adjacent crosstalk |
35 dB |
35 dB |
Maximum polarization dependent loss (PDL) |
0.7 dB |
0.7 dB |
Optical power setting accuracy |
+0.5 dB |
+0.5 dB |
Connectors
|
||
Input/output ports Monitor ports |
LC LC |
LC LC |
Power
|
||
Card power draw Typical
Maximum
|
17W 25W |
17W 25W |
Physical
|
||
Size |
1 slot |
1 slot |
Supported shelf slots |
1-6, 12-17 |
1-6, 12-17 |
Ordering Information
Table 8. System Ordering Information2
Part Number |
Description |
15454-32MUX-O= |
32-channel multiplexer card, C-band, 100-GHz, MPO connectors for add path, LC connector for interconnection |
15454-32DMX-O= |
32-channel demultiplexer card, C-band, 100-GHz, MPO connectors for drop path, LC connectors for interconnection, includes one 2-m LC/LC fiber-optic cables |
15454-4MD-xx.x= |
4-channel multiplexer and demultiplexer card, C-band, 100-GHz, LC connectors, includes two 2-m LC/LC fiber-optic cables |
15454-AD-1C-xx.x= |
1-channel OADM, C-band, 100-GHz, LC connectors, includes two 2-m LC/LC fiber-optic cables |
15454-AD-2C-xx.x= |
2-channel OADM, C-band, 100-GHz, LC connectors, includes two 2-m LC/LC fiber-optic cables |
15454-AD-4C-xx.x= |
4-channel OADM, C-band, 100-GHz, LC connectors, includes two 2-m LC/LC fiber-optic cables |
15454-AD-1B-xx= |
1-band OADM, C-band, 100-GHz, LC connectors, includes two 2-m LC/LC fiber-optic cables |
15454-AD-4B-xx= |
4-band OADM, C-band, 100-GHz, LC connectors, includes two 2-m LC/LC fiber-optic cables |
Table 9. Wavelength Ordering Information (value to use for part number in Table 8)
Wavelength (nm) |
Cisco 32-Channel Plan |
AD-1C |
AD-2C |
AD-4C |
AD-1B |
AD-4B |
1530.33 |
X |
30.3 |
30.3 |
30.3 |
30.3 |
30.3 |
1531.12 |
X |
31.1 |
||||
1531.90 |
X |
31.9 |
31.9 |
|||
1532.68 |
X |
32.6 |
||||
1534.25 |
X |
34.2 |
34.2 |
34.2 |
34.2 |
|
1535.04 |
X |
35.0 |
||||
1535.82 |
X |
35.8 |
35.8 |
|||
1536.61 |
X |
36.6 |
||||
1538.19 |
X |
38.1 |
38.1 |
38.1 |
38.1 |
|
1538.98 |
X |
38.9 |
||||
1539.77 |
X |
39.7 |
39.7 |
|||
1540.56 |
X |
40.5 |
||||
1542.14 |
X |
42.1 |
42.1 |
42.1 |
42.1 |
|
1542.94 |
X |
42.9 |
||||
1543.73 |
X |
43.7 |
43.7 |
|||
1544.53 |
X |
44.5 |
||||
1546.12 |
X |
46.1 |
46.1 |
46.1 |
46.1 |
46.1 |
1546.92 |
X |
46.9 |
||||
1547.72 |
X |
47.7 |
47.7 |
|||
1548.51 |
X |
48.5 |
||||
1550.12 |
X |
50.1 |
50.1 |
50.1 |
50.1 |
|
1550.92 |
X |
50.9 |
||||
1551.72 |
X |
51.7 |
51.7 |
|||
1552.52 |
X |
52.5 |
||||
1554.13 |
X |
54.1 |
54.1 |
54.1 |
54.1 |
|
1554.94 |
X |
54.9 |
||||
1555.75 |
X |
55.7 |
55.7 |
|||
1556.55 |
X |
56.5 |
||||
1558.17 |
X |
58.1 |
58.1 |
58.1 |
58.1 |
|
1558.98 |
X |
58.9 |
||||
1559.79 |
X |
59.7 |
59.7 |
|||
1560.61 |
X |
60.6 |
Additional Information
SKU | 15454-AD-4C30.3-RF |
---|---|
Weight (Kg) | 1 |
Datasheet URL | http://www.cisco.com/c/en/us/products/collateral/optical-networking/ons-15454-series-multiservice-provisioning-platforms/product_data_sheet09186a00801a5572.html |
Condition | Refresh |
Module Type | Optical Add/Drop Multiplexer |