15454E-AIC-I-RF

Double click on above image to view full picture

Zoom Out
Zoom In

15454E-AIC-I-RF

Description:

Cisco Refurbished
Original Part No : 15454E-AIC-I=

SDH AlarmInterconnect moduleANSI/ETSI Support REMANUFACTURED
AED 0

Availability: In stock


Available Quantity: 3500

Delivery Time: 2 to 4 week

  • Add to Compare
  • Details

    Data Sheet


    Advanced Alarm Interface Controller

    for the Cisco ONS 15454

    The advanced Alarm Interface Controller Card (AIC-I) shown in Figure 1 further advances the capabilities of the Cisco ONS 15454 SONET and SDH multiservice provisioning platforms, enabling greater network monitoring for improved network reliability.

    Figure 1

    Alarm Interface Controller Card (AIC-I) for Cisco ONS 15454

     

    Background

    Service providers and enterprise customers continue to look for ways to improve their profitability through lower operating costs. The new AIC-I card allows network administrators to better monitor the health of the network, with additional visibility to the operations in remote, unstaffed facilities. The AIC-I card extends the capability of the Cisco ONS 15454 to retrieve environmental alarms and monitor the health of the system's power source. The AIC-I card supports standard orderwire capabilities as well as Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH) overhead-based data channels, lowering the user's need for ancillary leased lines to support inter-central office and management connectivity. These features help reduce the overall costs of operating a network, resulting in improved return on investment (ROI).

    Cisco AIC-I Solution

    The AIC-I is a single-slot-wide card installable in the central card slot (#9) of the Cisco ONS 15454 SONET and SDH platforms. The card is optional and it advances the overall platform through the following feature enhancements:

    Increased environmental contact closure support

    Input voltage monitoring (SONET)

    User data channels

    Orderwire

    Environmental Alarms

    The AIC-I card enables the monitoring and event reporting of environmental conditions at remote facilities, and provides the ability to activate remote systems (Figure 2), such as warning lights and sirens, and secondary-power-generation equipment. The Cisco ONS 15454 AIC-I equipped SONET/ANSI shelf assembly will support up to 16 shelf-terminated alarm inputs and up to four shelf-terminated, Form-A output contact closures (provisionable as either inputs or outputs) with expansion capability to 32 inputs and 16 outputs with the use of an optional rear-chassis external Alarm Expansion Panel (AEP), shown in Figure 5. The Cisco ONS 15454 AIC-I equipped SDH/ETSI shelf assembly will support 16 shelf-terminated alarm inputs and four shelf-terminated alarm outputs via the MIC-A/P FMEC card. The alarm inputs are provisionable for contact activation (normally open or normally closed), severity (critical, major, minor, or external condition), and alarm description.

    Figure 2

    Environmental Alarm and Power Monitoring

     

    Voltage Monitoring (SONET/ANSI Systems)1

    The voltage monitoring function enables the user to proactively determine the health of the input power source to the Cisco ONS 15454 SONET. The AIC-I will enable the reporting and alarming of voltage threshold crossings, providing visibility into network changes.

    1 Input voltage monitoring is supported on the Cisco ONS 15454 SDH platform via the TCC-I card in conjunction with the MIC-A/P FMEC card.

    Data Channels

    The AIC-I data channels feature enables the use of SONET overhead bandwidth for the creation of data links for the network administrator's use, such as a data communication network for remote management data (Figure 3). The Cisco ONS 15454 AIC-I equipped system allows up to four point-to-point circuits to be created using the SONET/SDH overhead bytes. Two circuits are provisioned using the F1 byte in the Section/Regenerator Section overhead, each providing a 64 kbps data channel. The mechanical interface for these channels is via two RJ-11 connectors located on the faceplate of the AIC-I card. The remaining two circuits are provisioned over the D4-D12 bytes in the Line/Multiplex Section overhead, providing 576 kbps data channels. The mechanical interface to these channels is via two RJ-45 connectors located on the faceplate of the AIC-I card.

    Figure 3

    Data Channels for Remote Equipment Management

     

    Orderwire

    The AIC-I orderwire feature enables the craft technicians to communicate between network elements via bandwidth dedicated on the SONET/SDH overhead bytes (Figure 4). The voice channels use the E1 and E2 bytes of the SONET section overhead (SOH) / SDH regenerator section overhead (RSOH) and SONET line overhead (LOH) / SDH multiplex section overhead, respectively. The AIC-I card accepts the input from a standard telephone (two- or four-wire) or technician telephone test set and encodes the voice channel using A-Law or Mu-Law pulse code modulation (PCM). Each AIC-I card can be provisioned with a four-digit station number for selective card-to-card connection calling. A built-in call buzzer and LED are provided to alert the craft technician to an incoming call.

    Figure 4

    Communication via Orderwire Channels

     

    Cisco ONS 15454 AIC-I Features and Specifications

    Features are described below, followed by technical specifications of the AIC-I card in Table 1 and the AEP in Table 2. Product part numbers with descriptions are listed in Table 3.

    Alarm Contacts

    Up to 48 contacts per shelf for Cisco ONS 15454 SONET platform and 20 contacts for Cisco ONS 15454 SDH platform

    Provisionable parameters

    Normally open or normally closed for inputs contacts

    Alarm severity (critical, major, minor, external condition, service affecting, nonservice affecting)

    Alarm description

    Power Monitoring

    Proactively monitors the health of the system input voltage and notifies of condition changes

    Data Channels

    Two 64 kbps data channels (F1 byte of SONET section/SDH regenerator section overhead)

    Two 576 kbps data channels (D4-12 bytes of SONET line/SDH multiplexing section overhead)

    Reduces the need for ancillary leased-line data circuits between central offices

    System Requirements

    Cross-connect card: Any

    Timing, communications and control processor card: TCC+ (SONET) or TCC-I (SDH)

    Shelf assembly: NEBS3E, ANSI and ETSI shelf assemblies

    System software: R3.4 or greater

    Compliance

    Network Equipment Building Standards (NEBS) Level 3 compliant (GR-63-CORE, GR-1089-CORE)

    EN 60950 and ETS 300 386-1

    TR-NWT-000332, Issue 4, Method 1 calculation for 20-year mean time between failure (MTBF)

    Figure 5

    Alarm Expansion Panel (AEP) on Cisco ONS 15454 ANSI Shelf Assembly

     

     

    Table 1  Technical Specifications for AIC-I Card

    SpecificationSONET/ANSI SpecificationSDH/ETSI Specification

    Environmental alarm contacts

       

    Inputs

    12 fixed plus 4 provisionable as inputs or outputs

    32 fixed (with AEP)

    16 fixed plus 4 provisionable as inputs or outputs

    Outputs

    4 (same 4 provisionable as above)

    16 fixed (with AEP)

    4 fixed (same 4 provisionable as above)

    Contact drivers

       

    Input closures

    32 VDC

    2 mA

    32 VDC

    2 mA

    Output closures (Form-A Relay)

    60 VDC

    100 mA

    60 VDC

    100 mA

    Voltage monitoring

       

    -48VDC systems

    Major alarm

    No alarm

    Major alarm

    ð -40.5 VDC

    -40.5 to -56.7 VDC

    Š -56.7 VDC

    Not applicable1

    -60VDC systems2

    No alarm

    Not applicable

    Not applicable1

    Connector types

       

    Alarm communication channel

    26-pin SSIO

    26-pin SSIO

    User data channel

    RJ-11 (2)

    RJ-11 (2)

    DCC channels

    RJ-45 (2)

    RJ-45 (2)

    Orderwire

    RJ-11 (2)

    RJ-11 (2)

    Contact closure mechanicals

       

    Cisco ONS 15454 shelf assembly

    Wire wrap pins, rear shelf, 16 pairs

    DB64 (MALE) on MIC-A/P card

    Orderwire PCM encoding

       
     

    Mu-Law

    A-Law

    Mu-Law

    Power (maximum)

       

    AIC-I card

    8.4 watts

    8.4 watts

    AEP

    2.5 watts

    Not applicable

    Data channel bandwidth

       

    User data channels (2):

    F1 byte (2)

    64 kbps

    64 kbps

    Data communication channels (2):

    D4-D12 bytes

    576 kbps

    576 kbps

    Operating environment

       

    Temperature

    -40 to +65 °C

    -40 to +149 °F

    -40 to +65 °C

    -40 to +149 °F

    Humidity

    5 to 95%, noncondensing

    5 to 95%, noncondensing

    Storage environment

       

    Temperature

    -40 to +85°C

    -40 to +185 °F

    -40 to +85°C

    -40 to +185 °F

    Humidity

    5 to 95%, non-condensing

    5 to 95%, non-condensing

     

     

    Table 2  Technical Specifications: AEP—SONET/ANSI Platform Only

    SpecificationAEP

    Connector types

     

    Contact closures, inputs/outputs

    Two 50 pin AMP CHAMP

    Alarm communication channel

    Wire wrap

    Power (maximum)

     

    AEP

    2.5 watts

    Operating environment temperature

     

    Temperature

    -40 to +65 °C

    -40 to +149 °F

    Humidity

    5 to 95%, noncondensing

    Storage environment

     

    Temperature

    -40 to +85 °C

    -40 to +185 °F

    Humidity

    5 to 95%, noncondensing

     

     

    Specifications subject to change without notice.

    Table 3  Product Part Numbers and Descriptions

    Part NumberDescription

    15454-AIC-I

    Alarm Interface Controller, advanced, Cisco ONS 15454, SONET/ANSI platform, industrial temperature rated

    15454E-AIC-I

    Alarm Interface Controller, advanced, Cisco ONS 15454, SDH/ETSI platform, industrial temperature rated

    15454-AEP

    Alarm Expansion Panel, Cisco ONS 15454, SONET/ANSI platform only, industrial temperature rated

    Additional Information

    SKU 15454E-AIC-I-RF
    Weight (Kg) 1
    Datasheet URL http://www.cisco.com/en/US/products/hw/optical/ps2006/products_data_sheet09186a00800dd662.html
    Condition Refresh
    Module Type Optical Networking Module