Details
This data sheet provides detailed product specifications for an important element of the Cisco® Ethernet Optimized solutions: the Cisco CRS 4-Port 40GE LAN/OTN Interface Module (Figure 1). The module connects directly into any 40 Gigabit Ethernet transport network, including traditional OC-768 transport networks, and provides four ports at 40 Gbps of data per port for 40 Gigabit Ethernet LAN physical layer (LAN-PHY) or Optical Transport Network (OTN) Transport Unit Level 3 (OTU-3) transport.
Challenge and Solution
Significant dense Packet over SONET (POS) deployments exist despite the overwhelming industry trend toward Ethernet. Operators are looking for POS-like operations, administration, and maintenance (OAM) functions at Ethernet price points with technologies such as OTN G.709 encapsulation. Some operators have traditional transponder systems that can operate only in OC-768 and OTU-3 modes.
In addition, bandwidth growth is leading all markets, including data center operators, to move to 40 Gigabit Ethernet in the aggregation layer to handle growth in the data center.
The Cisco CRS 4-Port 40GE LAN/OTN Interface Module addresses both these needs.
The 4-port 40GE module in OTN mode with multirate serial C Form-Factor Pluggable (CFP) Fiber with Scrambled Encoding (FR) optics addresses the requirements for POS such as OAM functions at Ethernet prices, and the 4-port 40GE module in LAN mode with CFP Long-Reach (LR) or CFP Short-Reach (SR) optics provides a dense 40 Gigabit Ethernet solution for data centers and 10 Gigabit Ethernet aggregation.
Product Specifications
Table 1 lists specifications for the Cisco CRS 4-Port 40GE LAN/OTN Interface Module.
Table 1. Product Specifications
Feature |
Description |
Chassis compatibility |
Compatible with all current Cisco CRS-1 and CRS-3 line-card chassis |
Software compatibility |
Cisco IOS® XR Software Release 4.2.3 or later for Cisco CRS-3 platform |
Protocols |
● 40 Gigabit Ethernet
● OTU-3
● Encapsulations: ARPA, IEEE 802.2/SAP, and IEEE 802.3/SNAP
● IEEE 802.x flow control
● IEEE 802.1q VLAN support and jumbo frames
● IEEE 802.1p tagging
● Source and destination MAC address accounting and VLAN accounting
|
Port density |
Four ports of 40 Gigabit Ethernet per physical-layer interface module (PLIM) slot |
POS feature summary |
Not applicable |
OTN (G.709) feature summary |
● ITU G.709
● Alarm reporting: Loss of signal (LOF), loss of OTN frame (LOF), and loss of OTN multiframe (LOM)
● OTU alarm indication signal (OTU-AIS), OTU backward defect indication (OTU-BDI), ODU alarm indication signal (ODU-AIS), ODU open connection indication (ODU-OCI), ODU locked (ODU-LCK), ODU backwards defect indication (ODU-BDI), ODU payload type identifier mismatch (ODU-PTIM), OTU signal fail (OTU_SF_BER), and OTU signal degrade (OTU_SD_BER)
● OTU_SF_BER and OTU_SD_BER alarms are based on monitoring of OTU BIP errors with a user-configurable threshold crossing
● Error counts: OTU BIP, OTU BEI, ODU BIP, and ODU BEI
● Threshold crossing alerts (TCAs) for OTU BIP errors (SM-TCA) and ODU BIP errors (PM-TCA) with user-configurable threshold
● Local (internal) and line (network) loopback
|
Reliability and availability |
● Online insertion and removal (OIR) without affecting system traffic
|
Network management |
● Cisco IOS XR Software command-line interface (CLI)
● Simple Network Management Protocol (SNMP)
● XML interface
● CraftWorks Interface (CWI)
|
Physical dimensions |
● Occupies one PLIM slot
● Weight: 11.8 lb (5.3 kg)
● Height: 20.6 in. (52.32 cm)
● Depth: 11.2 in. (28.4 cm)
● Width: 1.8 in. (4.57 cm)
|
Power |
● 185W
|
Environmental conditions |
● Storage temperature: (–40 to 158°F (–40 to 70°C)
● Operating temperature:
◦ Normal: 32 to 104°F (0 to 40°C)
◦ Short-term: 23 to 131°F (–5 to 55°C)
● Relative humidity:
◦ Normal: 5 to 85%
◦ Short-term: 5 to 90% but not to exceed 0.024 kg water/kg of dry air
Note: Short-term refers to a period of not more than 96 consecutive hours and a total of 360 hours, but not more than 15 instances in 1 year.
|
Approvals and Compliance
Table 2 provides standards compliance information, Table 3 provides additional specifications, and Table 4 provides performance monitoring parameters.
Table 2. Compliance and Agency Approvals
Feature |
Description |
Safety standards |
● UL/CSA/IEC/EN 60950-1
● IEC/EN 60825 Laser Safety
● ACA TS001
● AS/NZS 60950
● FDA–Code of Federal Regulations Laser Safety
|
EMI |
● FCC Class A
● ICES 003 Class A
● AS/NZS 3548 Class A
● CISPR 22 (EN55022) Class A
● VCCI Class A
● BSMI Class A
● IEC/EN 61000-3-2: Power Line Harmonics
● IEC/EN 61000-3-3: Voltage Fluctuations and Flicker
|
Immunity (basic standards) |
● IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV contact, 15-kV air)
● IEC/EN-61000-4-3: Radiated Immunity (10V/m)
● IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV power, 1-kV signal)
● IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)
● IEC/EN-61000-4-5: Signal Ports (1 kV)
● IEC/EN-61000-4-5: Surge DC Port (1 kV)
● IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10 Vrms)
● IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
● IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations
|
ETSI and EN |
● EN300 386: Telecommunications Network Equipment (EMC)
● EN55022: Information Technology Equipment (Emissions)
● EN55024: Information Technology Equipment (Immunity)
● EN50082-1/EN-61000-6-1: Generic Immunity Standard
|
Network Equipment Building Standards (NEBS) |
This product is designed to meet the following requirements (qualification in progress): ● SR-3580: NEBS Criteria Levels (Level 3)
● GR-1089-CORE: NEBS EMC and Safety
● GR-63-CORE: NEBS Physical Protection
|
All specifications in Table 3 are worst-case values for the operational life of the product.
Table 3. Additional Specifications:
40 Gigabit Ethernet CFP Optics |
Specifications |
CFP-40G-SR4 |
Supports link lengths of up to 100m and 150m over laser-optimized OM3 and OM4 multimode fibercables, respectively |
CFP-40G-LR4 |
Supports link lengths of up to 10 km over a standard pair of G.652 single-mode fiber with duplexSCconnectors |
CFP-40G-FR |
Supports link lengths of up to 2 km over a standard pair of single-mode fiber with duplex SCconnectors |
Additional Information
SKU | 4-40GE-LAN/OTN-RF |
---|---|
Weight (Kg) | 1 |
Datasheet URL | http://www.cisco.com/c/en/us/products/collateral/routers/carrier-routing-system/data_sheet_c78-717299.html |
Condition | Refresh |
Module Type | LAN/OTN Interface Module |