N7K-C7010-RF

Double click on above image to view full picture

Zoom Out
Zoom In

N7K-C7010-RF

Description:

Cisco Refurbished
Original Part No : N7K-C7010=

10 Slot Chassis, No PowerSupply,Fans Included REMANUFACTURED
AED 0

Availability: In stock


Available Quantity: 25000

Delivery Time: 2 to 4 week

  • Add to Compare
  • Details

    Product Overview

    Cisco Nexus® 7000 Series Switches combine high levels of scalability with operational flexibility.

    Cisco Nexus 7000 Series Switches provide the foundation for Cisco® Unified Fabric. They are a modular data center-class product line designed for highly scalable 1/10/40/100 Gigabit Ethernet networks with a fabric architecture that scales beyond 17 terabits per second (Tbps). Designed to meet the requirements of the most mission-critical data centers, the switches deliver continuous system operation and virtualized, pervasive services. The Cisco Nexus 7000 Series is based on the proven Cisco NX-OS Software operating system, with enhanced features to deliver real-time system upgrades with exceptional manageability and serviceability.

    The first in the next generation of switch platforms, the Cisco Nexus 7000 Series (Figure 1) provides integrated resilience combined with features optimized specifically for the data center for availability, reliability, scalability, and ease of management.

    Figure 1.      Cisco Nexus 7000 Series

    Features and Benefits

    Coupled with Cisco NX-OS, the Cisco Nexus 7000 Series delivers a comprehensive set of features with nonstop operation in four chassis form factors:

       18-slot chassis with 18 front-accessible module slots and side-to-side airflow in a compact horizontal form factor with purpose-built integrated cable management.

       10-slot chassis with 10 front-accessible vertical module slots and front-to-back airflow and an integrated cable management system.

       9-slot with 9 front-accessible module slots and side-to-side airflow in a compact horizontal form factor with purpose-built integrated cable management.

       4-slot chassis with all front-accessible module slots and side-to-back airflow in a small form factor with purpose-built integrated cable management.

    All Cisco Nexus 7000 Series chassis use a passive mid-plane architecture, providing physical connectors and copper traces for interconnecting the fabric modules and the I/O modules for direct data transfer. All intermodule switching is performed via the crossbar fabric ASICs on the individual I/O modules and fabric modules. In the case of Cisco Nexus 7004 chassis, since there are no fabric modules, the mid-plane provides the connectors and traces to interconnect the fabric ASICs on the I/O modules directly.

    A scalable, fully distributed fabric architecture composed of up to five fabric modules combined with the chassis midplane delivers up to 550 Gbps per slot for 8.8 Tbps, 9.9 Tbps, and 18.7 Tbps of forwarding capacity in the 9-slot, 10-slot, and 18-slot switches, respectively. The 4-slot chassis delivers up to 1.92 Tbps of forwarding capacity in combination with the built-in fabric system.

    The midplane design on the 9-slot, 10-slot, and 18-slot chassis and the backplane design on the 4-slot chassis support flexible technology upgrades as your needs change, providing ongoing investment protection.

    Cisco Nexus 7000 4-Slot Switch Chassis

    The Cisco Nexus 7000 4-Slot chassis with two I/O module slots supports up to 96 x 1 and 10 Gigabit Ethernet ports, 12 x 40 Gigabit Ethernet ports and 4 x 100 Gigabit Ethernet ports, meeting the needs of small to medium-size data centers, co-locations, access- and aggregation-layer deployments, high-speed core deployments, and smaller operation zones. The Cisco Nexus 7000 4-Slot chassis also has two dedicated supervisor slots to provide full redundancy and high availability. The 4-slot chassis does not require fabric modules. The local I/O module fabrics are connected back to back to form a two-stage crossbar that interconnects the I/O modules and the supervisor engines. The backplane capacity is determined by the installed I/O modules.

       Side-to-rear airflow increases the system density in a seven-rack-unit (7RU) footprint, optimizing the use of rack space. The optimized density provides the capability to stack up to six 4-slot chassis in a 42RU rack.

       The fan tray with built-in fan and controller redundancy helps ensure reliability of the system and support for hot swapping of fan trays. The fan tray is on the top side of the chassis and draws the air from the right side of the chassis through the line card and supervisor slots and propagates it through the empty space on the left side of the chassis. The air then flows up to the fan tray on the top side and finally flows out from the vent holes on the back side of the chassis.

       Even though Nexus 7004 does not have fabric modules, fabric redundancy is still provided. If the local fabric on one of the I/O modules fails, the entire I/O module is taken offline.

       All modules, including power supplies and the fan tray, are accessible from the front.

    Cisco Nexus 7000 9-Slot Switch Chassis

       The Cisco Nexus 7000 9-Slot chassis with up to seven I/O module slots supports up to 336 x 1 and 10 Gigabit Ethernet ports, 42 x 40 Gigabit Ethernet ports, and 14 x 100 Gigabit Ethernet ports, meeting the demands of mission-critical campus core and data center deployments. It has two dedicated supervisor slots to provide full redundancy.

       Side-to-side airflow increases the system density in a 14RU footprint, optimizing the use of rack space. The optimized density provides the capability to stack up to three 9-slot chassis in a 42RU rack.

       Independent variable-speed system and fabric fans provide efficient cooling capacity to the entire system. Fan-tray redundancy features help ensure reliability of the system and support for hot swapping of fan trays.

       I/O modules, supervisor modules, and fabric modules are accessible from the front. Power supplies and fan trays are accessible from the back.

    Cisco Nexus 7000 10-Slot Switch Chassis

       The Cisco Nexus 7000 10-Slot chassis with up to eight I/O module slots supports up to 384 x 1 and 10 Gigabit Ethernet ports, 48 x 40 Gigabit Ethernet ports, and 16 x 100 Gigabit Ethernet ports, meeting the demands of large data center deployments. It has two dedicated supervisor slots to provide full redundancy.

       Front-to-back airflow helps ensure that use of the Cisco Nexus 7000 10-Slot chassis addresses the requirement for hot-aisle and cold-aisle deployments without additional complexity.

       The system uses dual system and fabric fan trays for cooling. Each fan tray is redundant and composed of independent variable-speed fans that automatically adjust to the ambient temperature, helping reduce power consumption in well-managed facilities while helping enable optimum operation of the switch. The system design increases cooling efficiency and provides redundancy capabilities, allowing hot swapping without affecting the system; if either a single fan or a complete fan tray fails, the system continues to operate without a significant degradation in cooling capacity.

       The system supports an optional air filter to help ensure clean air flow through the system. The addition of the air filter satisfies Network Equipment Building Standards (NEBS) requirements.

       I/O modules and supervisor modules are accessible from the front, and fabric modules, power supplies, and fan trays are accessible from the back.

    Cisco Nexus 7000 18-Slot Switch Chassis

       The Cisco Nexus 7000 18-Slot chassis with up to 16 I/O module slots supports up to 768 x 1 and 10 Gigabit Ethernet ports, 96 x 40 Gigabit Ethernet ports, and 32 x 100 Gigabit Ethernet ports, meeting the demands of the largest data center deployments. It has two dedicated supervisor slots to provide full redundancy.

       Side-to-side airflow increases the system density in a 25RU footprint, optimizing the use of rack space. The optimized density provides more than 16RU of free space in a standard 42RU rack for cable management and patching systems.

       Independent variable-speed system and fabric fans provide efficient cooling capacity to the entire system. Fan-tray redundancy features help ensure reliability of the system and support for hot swapping of fan trays.

       I/O modules and supervisor modules are accessible from the front, and fabric modules, power supplies, and fan trays are accessible from the back.

    Cisco Nexus 7000 Series Chassis Common Components

    All Cisco Nexus 7000 Series chassis have the following components:

       Integrated cable management system designed to support the cabling requirements of a fully configured system at either or both sides of the switch, allowing outstanding flexibility. All system components can easily be removed with the cabling in place, providing ease of maintenance tasks with little disruption.

       A series of LEDs at the top of the chassis provide a clear summary of the status of the major system components, alerting operators to the need to conduct further investigation. These LEDs report the power supply, fan, fabric, supervisor, and I/O module status.

       A purpose-built optional front-module door provides protection from accidental interference with both the cabling and modules installed in the system. The transparent front door allows easy observation of cabling and module indicators and status lights without any need to open the doors, reducing the likelihood of faults caused by human interference. The door supports a dual-opening capability for flexible operation and cable installation while fitted. The door can easily be completely removed for both initial cabling and day-to-day management of the system.

    Energy-Efficient Design

    The Cisco Nexus 7000 Series uses power supplies that are up to 90 percent efficient, so less power is wasted as heat, and more power is available for the system to use than with typical power supplies.

    The fan modules in the chassis adjust to compensate for changing thermal characteristics. At lower speeds, they use less power. In the 9-slot chassis, the fan tray is designed to completely turn off the power for a row of fans when the corresponding slots are unused.

    Consolidation of multiple switches in the Cisco Nexus 7000 Series is enabled by the powerful combination of high density and performance, support for device virtualization, and comprehensive reliability and availability features. This consolidation increases the power efficiency by reducing wasted power from multiple partially loaded and inflexible systems.

    Product Specifications

    Table 1 lists the product specifications for the Cisco Nexus 7000 Series chassis.

    Table 1.       Product Specifications

    Item

    Specification

     

    Cisco Nexus 7000 4-Slot Switch

    Cisco Nexus 7000 9-Slot Switch

    Cisco Nexus 7000 10-Slot Switch

    Cisco Nexus 7000 18-Slot Switch

    Product compatibility

    Supports all Cisco Nexus 7000 Series Supervisor and I/O modules except the following:

    N7K-SUP1

    N7K-M132XP-12

    N7K-M148GS-11

    N7K-M148GT-11

    N7K-F132XP-15

    Does not use fabric modules

    Supports all Cisco Nexus 7000 Series Supervisor and I/O modules

    Supports Fabric2 modules

    Does not support Fabric1 modules

    Supports all Cisco Nexus 7000 Series Supervisor and I/O modules

    Supports Fabric1 and Fabric2 modules

    Supports all Cisco Nexus 7000 Series Supervisor and I/O modules

    Supports Fabric1 and Fabric2 modules

    Software compatibility

    Cisco NX-OS Software Release 6.1(2) or later

    Cisco NX-OS Software Release 5.2 or later

    Cisco NX-OS Software Release 4.0 or later

    Cisco NX-OS Software Release 4.1 or later

    Options

    Lockable front module door

    Lockable front module door

      Air filter
      Lockable front module doors

    Lockable front module door

    Performance

    1.44 billion packets per second (bpps) (IPv4 Unicast) in combination with supervisor module and built-in fabric

    5.04 bpps (IPv4 unicast) in combination with supervisor and fabric modules

    5.76 bpps (IPv4 unicast) in combination with supervisor and fabric modules

    11.5 bpps (IPv4 unicast) in combination with supervisor and fabric modules

    Reliability and availability

    Online insertion and removal (OIR) of all redundant components: supervisor modules, power supplies, and fan trays

    OIR of all redundant components: supervisor and fabric modules, power supplies, and fan trays

    OIR of all redundant components: Supervisor and fabric modules, power supplies, and fan trays

    OIR of all redundant components: supervisor and fabric modules, power supplies, and fan trays

    MIBs

    Supports Simple Network Management Protocol (SNMP) Versions 3, 2c, and 1 (see Cisco NX-OS Software release notes for details about specific MIB support)

    Supports SNMPv3, v2c, and v1 (see Cisco NX-OS Software release notes for details about specific MIB support)

    Supports SNMPv3, v2c, and v1 (see Cisco NX-OS Software release notes for details about specific MIB support)

    Supports SNMPv3, v2c, and v1 (see Cisco NX-OS Software release notes for details about specific MIB support)

    Network management

    Cisco Data Center Network Manager (DCNM) 6.1.(2) or later

    Cisco DCNM 5.2 or later

    Cisco DCNM 4.0 or later

    Cisco DCNM 4.1 or later

    Programming interfaces

      XML
      Scriptable command-line interface (CLI)
      Cisco DCNM 6.1(2) web services
      XML
      Scriptable CLI
      Cisco DCNM 5.2 web services
      XML
      Scriptable CLI
      Cisco DCNM 4.0 web services
      XML
      Scriptable CLI
      Cisco DCNM 4.1 web services

    Physical specifications

      Usable rack space: 7RU
      4-slot chassis: 2 dedicated supervisor modules and 2 I/O modules
      4 power supply slots
      Dimensions (H x W x D): 12.2 x 17.3 x 24 in. (30.9 x 43.9 x 61 cm)
      Chassis depth including cable management and chassis doors is 29.6 in. (75.2 cm)
      Unit is rack mountable in a standard 19-inch (482.6-mm) Electronic Industries Alliance (EIA) rack
      Weight
       Chassis only: 45 lb. (20 kg)
       Fully configured: 120 lb. (54 kg)
      Power requirements: 110 to 240 VAC
      Supports 3-kW AC/DC power supplies
      Supports up to 6 chassis stacked in a 42RU rack
      Usable rack space: 14RU
      9-slot chassis: 2 dedicated supervisor modules and 7 I/O modules
      5 fabric module slots
      2 power supply slots
      Dimensions (H x W x D): 24.5 x 17.3 x 24 in. (62.2 x 43.9 x 61 cm)
      Chassis depth including cable management and chassis doors is 29 in. (73.7 cm)
      Unit is rack mountable in a standard 19-inch (482.6-mm) EIA rack
      Weight
       Chassis only: 100 lb. (45 kg)
       Fully configured: 300 lb. (136 kg)
      Power requirements: 110 to 240 VAC
      Supports 6- to 7.5-kW AC and DC power supplies
      Supports up to 3 chassis stacked in a 42RU rack
      Usable rack space: 21RU
      10-slot chassis: 2 dedicated supervisor modules and 8 I/O modules
      5 fabric module slots
      3 power supply slots
      Dimensions (H x W x D): 36.5 x 17.3 x 33.1 in. (92.7 x 43.9 x 84.1 cm)
      Chassis depth including cable management and chassis doors is 38 in. (96.5 cm)
      Unit is rack mountable in a standard 19-inch (482.6-mm) EIA rack
      Weight
       Chassis only: 200 lb. (90 kg)
       Fully configured: 516 lb. (235 kg)
      Power requirements: 110 to 240 VAC
      Supports 6- to 7.5-kW AC and DC power supplies
      Usable rack space: 25RU
      18-slot chassis: 2 dedicated supervisor modules and 16 I/O modules
      5 fabric module slots
      4 power supply slots
      Dimensions (H x W x D): 43.5 x 17.3 x 33.1 in. (110.5 x 43.9 x 84.1 cm)
      Chassis depth including cable management and chassis doors is 38 in. (96.5 cm)
      Unit is rack mountable in a standard 19-inch (482.6-mm) EIA rack
      Weight
       Chassis only: 187 lb. (85 kg)
       Fully configured: 696 lb. (316 kg)
      Power requirements: 110 to 240 VAC
      Supports 6- to 7.5-kW AC and DC power supplies

    Environmental specifications

      Airflow direction: Side to rear
      Operating temperature: 32 to 104°F (0 to 40°C)
      Operational relative humidity: 5 to 90%, noncondensing
      Operating altitude: -500 to 13,123 ft. (agency certified 0 to 6500 ft.)
      Seismic: Zone 4 per GR63
      Floor loading: 42 lb. per sq. ft.
      Operational vibration
      GR63, Section 5.4.2
      ETS 300 019-1-3, Class 3.1, Section 5.5
      Storage altitude: -1000 to 30,000 ft.
      Storage temperature: -40 to 158°F (-40 to 70°C)
      Storage relative humidity: 5 to 95%, noncondensing
      Heat dissipation: Maximum 3500W per chassis (actual dissipation will be lower, depending on the chassis configuration)
      Airflow direction: Side to side
      Operating temperature: 32 to 104°F (0 to 40°C)
      Operational relative humidity: 5 to 90%, noncondensing
      Operating altitude: -500 to 13,123 ft. (agency certified 0 to 6500 ft.)
      Seismic: Zone 4 per GR63
      Floor loading: 104 lb. per sq. ft.
      Operational vibration
      GR63, Section 5.4.2
      ETS 300 019-1-3, Class 3.1, Section 5.5
      Storage altitude: -1000 to 30,000 ft.
      Storage temperature: -40 to 158°F (-40 to 70°C)
      Storage relative humidity: 5 to 95%, noncondensing
      Heat dissipation: Maximum 7500W per chassis (actual dissipation will be lower, depending on the chassis configuration)
      Airflow direction: Bottom front of chassis to top back
      Operating temperature: 32 to 104°F (0 to 40°C)
      Operational relative humidity: 5 to 90%, noncondensing
      Operating altitude: -500 to 13,123 ft. (agency certified 0 to 6500 ft.)
      Seismic: Zone 4 per GR63
      Floor loading: 190 lb. per sq. ft.
      Operational vibration
      GR63, Section 5.4.2
      ETS 300 019-1-3, Class 3.1, Section 5.5
      Storage altitude: 1000 to 30,000 ft.
      Storage temperature: -40 to 158°F (-40 to 70°C)
      Storage relative humidity: 5 to 95%, noncondensing
      Heat dissipation: Maximum 12,000W per chassis (actual dissipation will be lower, depending on the chassis configuration)
      Airflow direction: Side to side
      Operating temperature: 32 to 104°F (0 to 40°C)
      Operational relative humidity: 5 to 90%, noncondensing
      Operating altitude: -500 to 13,123 ft. (agency certified 0 to 6500 ft.)
      Seismic: Zone 4 per GR63
      Floor loading: 190 lb. per sq. ft.
      Operational vibration
      GR63, Section 5.4.2
      ETS 300 019-1-3, Class 3.1, Section 5.5
      Storage altitude: 1000 to 30,000 ft.
      Storage temperature: -40 to 158°F (-40 to 70°C)
      Storage relative humidity: 5 to 95%, noncondensing
      Heat dissipation: Maximum 18,000W per chassis (actual dissipation will be lower, depending on the chassis configuration)

    Regulatory compliance

      EMC compliance
      FCC Part 15 (CFR 47) (USA) Class A
      ICES-003 (Canada) Class A
      EN55022 (Europe) Class A
      CISPR22 (International) Class A
      AS/NZS CISPR22 (Australia and New Zealand) Class A
      VCCI (Japan) Class A
      KN22 (Korea) Class A
      CNS13438 (Taiwan) Class A
      CISPR24
      EN55024
      EN50082-1
      EN61000-3-2
      EN61000-3-3
      EN61000-6-1
      EN300 386

    Environmental standards

      NEBS criteria levels
      SR-3580 NEBS Level 3 (GR-63-CORE, issue 3, and GR-1089-CORE, issue 4)
      Verizon NEBS compliance
      Telecommunications Carrier Group (TCG) Checklist
      Qwest NEBS requirements
      Telecommunications Carrier Group (TCG) Checklist
      ATT NEBS requirements
      ATT TP76200 level 3 and TCG Checklist
      ETSI
      ETSI 300 019-1-1, Class 1.2 Storage
      ETSI 300 019-1-2, Class 2.3 Transportation
      ETSI 300 019-1-3, Class 3.2 Stationary Use
      Reduction of Hazardous Substances (ROHS) 5

    Safety

      UL/CSA/IEC/EN 60950-1
      AS/NZS 60950

    Warranty

    Cisco Nexus 7000 Series Switches come with the standard Cisco 1-year limited hardware warranty

    Software Requirements

    All Cisco Nexus 7000 Series chassis are supported by Cisco NX-OS Software.

       The 4-slot chassis requires Cisco NX-OS Software Release 6.1(2) or later.

       The 9-slot chassis requires Cisco NX-OS Software Release 5.2 or later.

       The 10-slot chassis requires Cisco NX-OS Software Release 4.0 or later.

       The 18-slot chassis requires Cisco NX-OS Software Release 4.1 or later.

    For the latest information about recommended releases, see http://www.cisco.com/en/US/docs/switches/datacenter/sw/nx-os/recommended_releases/recommended_nx-os_releases.html.

    Ordering Information

    To place an order, visit the Cisco Ordering homepage. To download software, visit the Cisco Software Center. Table 2 provides ordering information.

    Table 2.       Ordering Information

    Product Name

    Part Number

    System

    Cisco Nexus 7000 Series 9-Slot chassis including Fan Trays, No Power Supply

    N7K-C7009

    Cisco Nexus 7000 Series 9-Slot chassis No Fan Trays, No Power Supply

    N7K-C7009=

    Cisco Nexus 7000 Series-9-Slot Fan Tray Spare

    N7K-C7009-FAN=

    Cisco Nexus 7000 Series 4-Slot Chassis including Fan Tray, Cable Management Kit, No Power Supply

    N7K-C7004

    Cisco Nexus 7000 Series 4-Slot Chassis including Fan Tray, Cable Management Kit, No Power Supply

    N7K-C7004=

    Cisco Nexus 7000 Series 4-Slot Fan Tray Spare

    N7K-C7004-FAN=

    Cisco Nexus 7000 Series 10-Slot chassis including Fan Trays, No Power Supply

    N7K-C7010

    Cisco Nexus 7000 Series 10-Slot chassis including Fan Trays, No Power Supply

    N7K-C7010=

    Cisco Nexus 7000 Series-10-Slot System Fan Tray Spare

    N7K-C7010-FAN-S=

    Cisco Nexus 7000 Series-10-Slot Fabric Fan Tray Spare

    N7K-C7010-FAN-F=

    Cisco Nexus 7000 Series 18-Slot chassis including Fan Trays, No Power Supply

    N7K-C7018

    Cisco Nexus 7000 Series 18-Slot chassis No Fan Trays, No Power Supply

    N7K-C7018=

    Cisco Nexus 7000 Series-18-Slot Fan Tray Spare

    N7K-C7018-FAN=

    Cisco Nexus 7000 Series 4-Slot Accessories

    Cisco Nexus 7004 Rack Mount Kit

    N7K-C7004-RMK=

    Cisco Nexus 7004 Front Door Kit

    N7K-C7004-FD-MB

    Cisco Nexus 7004 Air Filter

    N7K-C7004-AFLT=

    Cisco Nexus 7000 Series 9-Slot Accessories

    Cisco Nexus 7009 Rack Mount Kit

    N7K-C7009-RMK=

    Cisco Nexus 7009 Front Top Section and Cable Mgmt Kit

    N7K-C7009-CAB-TOP=

    Cisco Nexus 7009 Front Door Kit

    N7K-C7009-FD-MB

    Cisco Nexus 7009 Bottom Support Kit

    N7K-C7009-BSK

    Cisco Nexus 7009 Fabric Module Blank

    N7K-C7009-F-BLANK=

    Cisco Nexus 7009 Center Mount Kit

    N7K-C7009-CMK

    Cisco Nexus 7000 Series 10-Slot Accessories

    Cisco Nexus 7010-Air Filter

    N7K-C7010-AFLT=

    Cisco Nexus 7000-Rack Mount Kit

    N7K-RMK=

    Cisco Nexus 7010-EMI Inlet Screen Kit

    N7K-C7010-EMI-SC=

    Cisco Nexus 7010 Front Door Top Section-including Cable Management Kit

    N7K-C7010-FD-TOP=

    Cisco Nexus 7010 Front Door-Kit

    N7K-C7010-FD-MB=

    Cisco Nexus 7000 Bottom Support Kit

    N7K-BSK=

    Cisco Nexus 7010 Fabric Module Blank

    N7K-FAB-BLANK=

    Cisco Nexus 7000 Series 18-Slot Accessories

    Cisco Nexus 7018 Rack Mount Kit

    N7K-C7018-RMK=

    Cisco Nexus 7018 Front Top Section and Cable Mgmt Kit

    N7K-C7018-CAB-TOP=

    Cisco Nexus 7018 Front Door Kit

    N7K-C7018-FD-MB

    Cisco Nexus 7018 Bottom Support Kit

    N7K-C7018-BSK

    Cisco Nexus 7018 Fabric Module Blank

    N7K-C7018-F-BLANK=

    Blank Panel Covers

    Cisco Nexus 7000 Series Supervisor Blank Slot Cover

    N7K-SUP-BLANK=

    Cisco Nexus 7000 Series Module Blank Slot Cover

    N7K-MODULE-BLANK=

    Cisco Nexus 7000 Series Network Clock Card Blank

    N7K-CLK-BLANK=

    Cisco Nexus 7000 Series 3 KW Power Supply Blank Slot Cover with Handle

    N7K-3KPS-BLANK-H=

    Cisco Nexus 7009 Chassis Power Supply Blank Slot Cover with Handle

    N7K-PS-BLANK-H=

    Cisco Nexus 7010 Chassis Power Supply Blank Slot Cover

    N7K-PS-BLANK=

    Cisco Nexus 7018 Chassis Power Supply Blank Slot Cover with Handle

    N7K-PS-BLANK-H=

    Service and Support

    Cisco offers a wide range of services to help accelerate your success deploying and optimizing Cisco Nexus 7000 Series Switches in your data center. Our innovative services are delivered through a unique combination of people, processes, tools, and partners, and are focused on helping you increase operation efficiency and improve your data center network. Cisco Advanced Services use an architecture-led approach to help you align your data center infrastructure with your business goals and provide long-term value. Cisco SMARTnet® Service helps you resolve mission-critical problems with direct access at any time to Cisco network experts and award-winning resources. With this service, you can take advantage of the Cisco Smart Call Home service capability, which offers proactive diagnostic information and real-time alerts for your Cisco Nexus 7000 Series Switches. Spanning the entire network lifecycle, Cisco Services helps increase investment protection, optimize network operations, provide migration support, and strengthen your IT expertise. For more information about Cisco Data Center Services, visit http://www.cisco.com/go/dcservices.

    Cisco Capital

    Financing to Help You Achieve Your Objectives

    Cisco Capital can help you acquire the technology you need to achieve your objectives and stay competitive.
    We can help you reduce CapEx. Accelerate your growth. Optimize your investment dollars and ROI. Cisco Capital financing gives you flexibility in acquiring hardware, software, services, and complementary third-party equipment. And there’s just one predictable payment. Cisco Capital is available in more than 100 countries. Learn more.

    For More Information

    For more information about the Cisco Nexus 7000 Series, visit the product homepage at http://www.cisco.com/go/nexus or contact your local account representative.

     

     

     

     

     

     

     

    Additional Information

    SKU N7K-C7010-RF
    Weight (Kg) 90
    Datasheet URL http://www.cisco.com/c/en/us/products/collateral/switches/nexus-7000-series-switches/Data_Sheet_C78-437762.html
    Condition Refresh
    Switch Series Nexus 7000 Series
    Device Type Modular
    Power Rating N/A
    Number of Access Ports None
    Access Port Speed Not Available
    Number of Uplink Ports None
    Uplink Ports Speed Not Available
    PoE Ports Non PoE
    Rack Mountable Yes
    Stackable Yes

    N7K-C7010-RF

    AED

    AED 0

    0